What winter here actually asks of a heat pump
Your heat runs seven months a year in Calvert County, October through April, and the overnight low averages 29°F across December, January and February. That number matters because a standard heat pump starts losing ground below 40°F and often needs backup heat below about 35°F. Your average winter night is already past both marks. So the question isn't whether a heat pump can handle a rare cold snap. It's whether it can handle a normal Tuesday in January.
About 80 nights a year here drop to freezing or below, roughly four nights in ten across the whole heating season. Every one of those nights is cold enough to put a standard heat pump into its weaker range. That doesn't mean the house goes cold. It means the system is leaning on backup heat, usually electric resistance, on a large share of the nights it's actually needed.
The nights that get seriously cold are rare. Fewer than one a year reaches 0°F, and only about 0.2 of the 80 freezing nights get that low. If you install a heat pump built to carry the ENERGY STAR Cold Climate rating, it's tested to hold 1.75 units of heat per unit of electricity even at 5°F, and keep most of its capacity down there. A heat pump built to the federal minimum, which is what the running cost figures below assume, isn't tested to that standard. Field tests of cold-climate models in occupied homes found backup heat carried only a small share of the load even between 0°F and 35°F. The gap between a minimum-spec heat pump and a cold-climate one is the real decision here, more than the gap between a heat pump and a furnace.