What winter here does to a heat pump
Your heat runs eight months a year here, October through May, and the overnight low averages 24°F across December, January and February. A standard heat pump starts losing ground before it even gets that cold. Below 40°F its heat output falls short of its rating. Below about 35°F it often needs backup heat to make up the difference. Your average winter night is past both marks.
About 125 nights a year here fall at or below freezing, roughly half the nights in the eight months the heat runs. That is not a cold snap you plan around once. That is most of an ordinary winter. Every one of those nights puts a standard heat pump below the 40°F and 35°F marks at the same time.
It rarely gets severely cold. About 2 nights a year reach 0°F. So the backup heat on a standard heat pump system is not there for a few extreme nights, it is covering a long stretch of ordinary nights in the 20s and 30s.
A heat pump built to the ENERGY STAR Cold Climate standard is tested against exactly that kind of cold. To earn the label it has to make at least 1.75 units of heat for every unit of electricity at 5°F, and hold on to at least 70 percent of its 47°F capacity at that temperature. That is a different machine than the federal minimum unit used for the running costs on this page. Field testing backs it up: over two winters in occupied homes, backup heat covered only a small share of the output between 0°F and 35°F, and running on backup alone was rare even above 0°F.
So the real answer depends on which heat pump you mean. A standard one will lean on backup heat through much of your winter. A cold-climate one is built for the conditions Allegany County actually has, long stretches in the 20s and 30s, not the rare night near zero.