Electricity here costs 17.86 cents a kilowatt-hour
Maryland homes paid that rate in 2024. A heat pump that has to work harder to move the same heat draws more power every hour it runs, and at that rate the difference shows up on the bill.
Takes about a minute. No obligation.
Maryland homes paid that rate in 2024. A heat pump that has to work harder to move the same heat draws more power every hour it runs, and at that rate the difference shows up on the bill.
Neither one stops your heat pump from running. They just make it use more power to do the same job, all winter and all summer, for as long as the problem sits there.
Half the homes in Allegany County were built in 1959 or earlier.
A heat pump in a house that old has likely had more than one owner, and a yearly check is how you find out what the last one missed.




A yearly check is what catches a dirty coil or a low charge before it spends a full season costing you money. A technician cleans the coil, checks the refrigerant charge, and makes sure the compressor is moving heat the way it should rather than straining to do it. That visit costs far less than a winter or a summer of higher draw at 17.86 cents a kilowatt-hour. Skip it and the system still runs, it just keeps working harder than it needs to, month after month, until something finally fails outright.
A yearly check is how you find out what a system with more than one owner has been dealing with. Get it looked at before heat season starts.
Find a contractorA heat pump moves heat in both directions, so the filter, the coils and the drain all take the hit year round. A clogged filter cuts airflow across the indoor coil, and when airflow drops the coil can ice up even while it's cooling. The outdoor coil picks up dust, pollen and grass clippings over time, and a dirty outdoor coil can't give up heat or pull it in as well as a clean one, so the system has to run longer to hit the same setting. The condensate drain matters just as much. Moisture collects on the indoor coil whenever the system cools, and if that drain line clogs with algae or sludge, the water backs up into the pan instead of draining away. From there it can trip a safety switch or spill over onto whatever sits below. None of this happens overnight. It builds up a little with every cycle the system runs.
A heat pump switches direction with a reversing valve, and that valve only moves when it gets told to. If it sits unused or picks up grime over a season, it can stick partway and leave the system blowing cool air when you called for heat. A yearly check cycles it on purpose, so it's known to move before the day you need it to.
The outdoor coil frosts up in cold weather, and the system is built to sense that and run a defrost cycle to clear it. A failing sensor or a dirty coil throws that timing off, and the unit either defrosts when it doesn't need to or skips a defrost it does need. Either way ice builds on the coil and stays there, and a frozen coil can't pull heat from outside air no matter how long the system runs.
A heat pump usually tells you something is off before it quits outright. It might run longer than it used to, cycling on and on without reaching the set temperature. It might blow air that feels cooler than it should for heat mode, or warmer than it should for cooling. You might hear a clicking at startup that wasn't there before, or notice ice on the outdoor unit that isn't clearing between defrost cycles. None of these mean the system is about to fail tomorrow. They mean something inside it, a sensor, a valve, a contact point, is starting to wear or drift out of adjustment, and a technician can usually catch it and adjust it before it turns into a breakdown.
A real tune-up is a set sequence, not a once-over. The technician checks refrigerant charge against what the system calls for, because too little or too much makes the compressor strain either way. They pull the panels and inspect the contactor and capacitor, the parts that get the compressor started and keep it running, since a worn capacitor is one of the more common reasons a heat pump short-cycles or won't start at all. They check amp draw on the compressor and fan motors against the rating on the nameplate, which catches a motor that's working harder than it should before it fails outright. The thermostat gets checked for accurate calibration, since a thermostat reading a few degrees off makes the whole system run longer than it needs to. They'll also check that the reversing valve shifts cleanly and that the defrost control is timing out correctly. None of these steps show up to the eye. That's the point of having someone check them on purpose, once a year, instead of finding out when one of them finally gives out.