What winter here does to a heat pump
Your heat runs seven months a year here, October through April, and the overnight low averages 28°F across December, January and February. That number matters because a standard heat pump has two different breakpoints below it. Below 40°F it starts putting out less heat than its rating says. Below about 35°F it often needs backup heat to make up the difference. An average winter night here is below both marks.
This is not a handful of bad nights. The overnight low hits freezing or below about 90 nights a year, close to half the nights across the whole heating season. On every one of those nights a standard heat pump is working under at least one of its two limits. That is the normal pattern here, not the exception.
It does not mean the house goes cold. Cold climate heat pumps exist and are rated for exactly this, holding at least 70 percent of their 47°F capacity at 5°F, checked by outside testing. A field test of prototype cold climate units over two winters found backup heat carried only a small share of the load even between 0°F and 35°F, and running on backup alone was rare above 0°F. The county's coldest nights barely reach that range anyway. Below 0°F happens less than one night a year here. A heat pump built for cold climates is the one to ask for if you are leaning that way, not the federal minimum unit the running cost numbers above are built on.