A dark gray furnace with two access panels stands in a basement, connected to galvanized sheet-metal ductwork and PVC pipes, with exposed wood framing and a bare bulb light in the background.

A pro who works on furnaces

Why your furnace ignitor keeps failing in Maryland

An ignitor that quits over and over usually means something else is making it work too hard, not a bad part each time. With most Maryland homes heating on electricity and power here costing real money, a furnace that keeps relighting itself is burning through both. This page gets into what causes it, and can connect you with a local contractor who works on furnaces like yours all winter and can take a closer look.

Match me with a pro

A furnace ignitor that fails again and again is usually a symptom, not just a worn part. Ignitors are rated for a set number of on-off cycles, and anything that makes the furnace cycle more than it should wears one out early. A dirty flame sensor, a clogged filter restricting airflow, or a cracked heat exchanger tripping a safety switch can all force the system to shut down and relight over and over, and each relight uses up more of the ignitor's life. In a lot of Maryland homes, where the furnace shares ductwork with electric central air and the system runs hard in both directions, that extra cycling adds up fast. Replacing the ignitor without finding what's driving the short cycling just buys you a few more months before it happens again. The real fix is tracing back to why the furnace is cycling in the first place, not just the part that gave out.

A woman in a gray turtleneck sweater stands by a window looking outside at snowy ground, with a dimly lit living room containing a sofa, shelves, lamp and a lit candle behind her.
A woman in a cream cable-knit turtleneck sweater stands in a warmly lit living room with a fireplace and shelves behind her, looking out a window toward snow-covered trees and a railed deck.
A woman in a cream knit turtleneck sweater stands by a window looking out at snow, with a lit fireplace, sofa and lamp in the room behind her.
A woman in a gray knit sweater sits by a window looking out at falling snow, with a dimly lit living room containing a sectional sofa, pillows, a lamp and houseplants behind her.
A gray high-efficiency furnace in a basement with PVC venting pipes, a yellow gas line, metal ductwork, concrete walls and floor, and a wood-framed stairway at left.

Running Normally

A furnace cycles on, builds a steady flame, and shuts off clean once the house reaches temperature. The ignitor glows, lights the gas, and goes dark again until the next call for heat. One cycle, one light, no drama.

A beige furnace with a louvered front panel and metal ductwork stands on a concrete basement floor beside pipes and a white cylindrical water heater.

Short Cycling

This furnace fires, runs a few minutes, and shuts off before the house warms up. Then it starts again. Each restart asks the ignitor to light the gas from cold, and that's the wear that burns one out long before it should quit.

A beige furnace with two louvered front panels stands on a concrete basement floor beside galvanized ductwork, metal pipes, and a wooden post.
Before you get your furnace repair
A gray high-efficiency furnace stands on a concrete basement floor beside galvanized sheet-metal ductwork, with white PVC vent pipes, gas and water lines, and unfinished wood framing behind it.
After you get your furnace repair

When your furnace calls for heat, the ignitor draws power for about 30 seconds, heating up before the gas valve opens. That surge is hard on the coil every single time, and it's the main thing that wears an ignitor down, not age by itself. A furnace is built to try ignition three or four times before it locks out for safety, so a unit that's short cycling runs through that budget fast. The control board checks for a flame a few seconds after ignition, and if it doesn't see one, it cuts the ignitor and tries again, repeating the same strain. If gas is slow to arrive, the ignitor sits at full heat longer than it should, which ages it faster even though the burners still light. Low voltage reaching the furnace causes similar damage, making the ignitor run too cool to light cleanly or too hot and brittle. Silicon nitride ignitors hold up better than the older silicon carbide type, but no ignitor is built to survive constant restarts.

How an Ignitor Actually Fails

  • A hot surface ignitor draws current for about 30 seconds before the gas valve opens, and that brief surge is what actually breaks the coil over time.
  • Most furnaces allow three or four ignition tries per call for heat before they lock out, so a short cycling furnace multiplies that strain fast.
  • A silicon nitride ignitor is more tolerant of repeated cycling than the older silicon carbide type, but neither survives constant restarts for long.
  • The control board reads the flame sensor after ignition, and if it doesn't detect a flame in a few seconds it cuts power and tries again.
  • A delayed or weak ignition still lights the burners, but the extra time the ignitor sits at full heat before gas arrives shortens its life.
  • Low line voltage to the furnace makes the ignitor glow at the wrong temperature, either too cool to light gas cleanly or hot enough to crack early.
A bearded man in a plaid flannel shirt stands in a kitchen looking out a window toward snow-covered shrubs, with a steaming mug on the windowsill and potted plants on a shelf behind him.
A smiling man with dark curly hair in a navy t-shirt sits on a gray couch indoors, with a large-leafed plant and a window in the background.
An unfinished basement with a concrete floor, pink insulation on one wall, exposed joists, galvanized sheet-metal ductwork, PVC vent pipes, and a tall gray furnace with attached gas and electrical lines.

Get your furnace to the right pro

Your request stays with one local pro.

Tell a local repair pro what your furnace is doing.

Find a local pro

You only hire the pro if you want to.

A gray high-efficiency furnace in a basement with white PVC vent pipes, sheet-metal ductwork, copper and black piping, a condensate pump, and insulated walls above a concrete floor.
A furnace that's sized and venting right lights once per cycle, and the ignitor only has to prove itself a few hundred times a year.
A beige residential furnace stands on a concrete basement floor beside galvanized sheet-metal ductwork, a round flue pipe, copper gas piping, and a PVC condensate line, with a wood-paneled wall at right.
A furnace fighting a cracked heat exchanger or a blocked flue trips its limit switch and restarts, asking the ignitor to do that job again and again.

What Repeat Failures Cost You

  • A furnace that relights three or four times on a cold morning is putting a year's worth of wear on the ignitor in a single week.
  • You may notice the blower running longer than usual, or the house taking longer to warm up between cycles.
  • Each failed ignitor call is a service visit you're paying for, and the part keeps failing until whatever is overworking it gets fixed.
  • A furnace that short cycles all winter pulls more power to restart again and again, and that shows up on a Maryland electric bill.
  • If the furnace locks out on cold nights, you're left waiting on a repair instead of catching a worn part before it quits.
  • A cracked heat exchanger or blocked flue behind the failures is a safety issue, not just an inconvenience.

A furnace that won't hold an ignitor is telling you something about how it's running, not just about that part. On a cold morning, three or four relight attempts in a row put a year's worth of wear on the coil before breakfast. You'll likely notice the blower staying on longer than it used to, or the house taking its time to come up to temperature between cycles. That's the furnace working harder to make up for whatever is tripping it into restarting.

Every time the ignitor fails, that's a service call, and paying for a new part doesn't fix anything if the real problem, whether it's a dirty flame sensor, a blocked flue or a furnace that's cycling more than it should, is still there. The next one wears out the same way. In Maryland, where most homes heat on electricity, a furnace restarting itself over and over all winter pulls extra power each time, and that adds up on your bill.

There's also what happens when the ignitor finally gives out for good. Furnaces allow a handful of ignition tries before they lock out, so a furnace that's already struggling is more likely to leave you without heat on the night you need it most, instead of giving you a part that's worn and failing before it quits for good. And if what's driving the short cycling is a cracked heat exchanger or a blocked flue, that's not just about bad luck with the ignitor. That's a safety problem sitting behind a part you keep replacing.

Winter nights average 27°F statewide

On a 27°F night your furnace isn't cycling once or twice, it's calling for heat most of the night to keep up. Every one of those calls asks the ignitor to light again. More lighting means more wear, and a part already stressed by short cycling fails that much sooner.

NOAA nClimDiv 1991-2020 county normals weighted by homes

A woman in a cream cardigan and jeans stands with one hand raised facing an open front door of a gray horizontal-siding house, with a black lantern wall light, a potted shrub with yellow flowers, and a stone-faced porch column.

A new ignitor won't fix what's making it fail

An ignitor that keeps going out is telling you something about the rest of the furnace. Swap the part without finding the cause and you'll be back here in a few weeks, out the cost of another ignitor with the same problem underneath it. The cause is usually something specific to your furnace: how it was sized for your house, what's happening in the flue, how clean the flame sensor is. That's a diagnosis, not a guess.

That's the kind of call that goes to someone who works on furnaces in Maryland homes all winter and has seen which parts tend to give out first when a furnace is cycling harder than it should. You'll be matched with one licensed local contractor for your situation, not a handful of companies competing for your number, and that contractor will reach out to you directly about what's going on with your furnace.

A living room corner with a beige upholstered armchair holding navy and striped cushions, a small round wooden side table with a carved bowl and a potted green plant, a framed landscape picture on a pale wall, built-in shelving, and a curtained window.
At dusk, a dark board-and-batten house with a standing-seam metal roof and lit entry walkway of stone pavers, with two large outdoor heat pump units on a stone-walled pad at right and trees and hills in the background.

Furnace Repair

The right pro for this job

RepairFurnace or heatingMaryland
Step 1 of 2

What ZIP code is the job in?

  • A ceramic vase holding leafy green branches and a shallow wooden bowl sit on a wooden window ledge beside a sunlit window, with a cream upholstered chair and knit throw in the foreground.
    • Say what's going on with your furnace, and a pro who works on them reaches out.
    • A local pro who knows furnaces gets your details and gets in touch.
  • Sunlit living room corner with a beige upholstered sofa, a round wooden side table holding a ceramic vase of olive branches, linen curtains at a window, a floor vent in the baseboard, and a woven jute rug on hardwood flooring.
    • Send it once and finding someone is no longer on you.
    • Send the request today and let a furnace pro reach out to you.
  • A wooden side table with a single drawer holds a shallow carved wood bowl and a white ceramic vase of green eucalyptus stems, beside a window and an upholstered chair draped with a cream knit throw.
    • Answer a few questions instead of calling shop after shop.
    • Describe your furnace job once, to one pro.
  • Corner of a house with horizontal siding, a white-framed window and stone veneer base, beside a covered entry with wooden steps, a potted plant, mulched beds of green shrubs and a flagstone path.
    • The pro who reaches out is licensed in Maryland.
    • Only one pro gets your request, so you hear from one company.